PCD Fixed an issue where cylinder computation from b-spline surfaces had poor accuracy. PCD Fixed an issue with BFRE constructions from offset points that did not contain ball center data. PCD Fixed an issue where, when Vision Diagnostics was turned on for features, a memory leak and resource leak occurred every time a measurement routine was executed. Laser features are now created if the active probe is a laser scanning sensor. PCD Corrected an issue where the File Import ASCII operation always generated tactile features even if the current probe was a laser probe. PCD Fixed an issue where PC-DMIS stopped working when the frequency parameters for the CWS sensor were copied and pasted. PCD Fixed an issue where the laser extraction of Circles, Round and Square Slots from a pointcloud failed when the nominal feature was on the lower layer of two overlapping, parallel sheetmetal surfaces. This caused the colormap to no longer be visible. PCD Fixed an issue where the Mesh Colormap reset when the mesh colormap dialog box was edited and then closed.

Pc dmis 2018 pathlines error manual#

1Ħ PCD Fixed an issue where a Vision Edge Point Auto Feature with a manual target and large crosshair had the crosshair shrink and disappear as the rotary angle went to 90 degrees. PCD Corrected an issue where, in some cases, laser auto features were not evaluated correctly when re-executed.

Pc dmis 2018 pathlines error software#

The behavior was caused by a change in the IDS software library. This could slow PC-DMIS or other applications running on the computer. PCD PC-DMIS Vision had a constant, high CPU usage when controlling an IDS ueye color camera. PCD Fixed an issue for laser auto sphere execution where the feature did not extract even though there was sufficient data. There are limitations in how small the font can be and still be readable in the Graphic Display window or report based on your computer's display resolution. Increasing the factor to 120 results in a smaller minimum font, and decreasing the value to 80 may result in a larger minimum font. The value is a factor with a default value of 100. You can set the minimum font size through the ColorGradientMinFontFactor registry entry in the Settings Editor application. Colormap scale values are now adjusted based on a minimum font size. PCD Corrected an issue where the values for all levels of the Pointcloud Colormap scale were not shown if the levels were very closely spaced.

Pc dmis 2018 pathlines error portable#

PCD Fixed a crash that sometimes occurred when a new inspection routine was opened or created online with the portable arm due to a problem with the CMS calibration file. PCD Fixed an issue where the Show both directions check box was incorrectly disabled when the Pointcloud Surface Colormap Scale was edited.

Pc dmis 2018 pathlines error install#

3 Contents Release Notes R1 SP Release Notes R1 SP Release Notes R1 SP Release Notes R1 SP Release Notes R1 SP Release Notes R1 SP Release Notes R1 SP Release Notes R Information about this Release Installing the Software Step 1: Check System and Hardware Requirements Step 2: Log on as an Administrator Step 3: Back Up Existing Settings Backing Up Machine Files for an Xcel CMM or a Sharpe Controller Backing Up Machine Files for a CMM with a DEA Controller Step 4: Install the Software LMS License Setup Administrator Privileges Explained Step 5: Copy Files after Installation Copying Machine Files for an Xcel CMM or a Sharpe Controller Copying Machine Files for a DEA CMM with a DEA Controller Step 6: Launch the Software for the First Time Note About CMMs Using RS-232 Communications Updating the Software Repairing or Removing an Installation Running the Software in Another Language Installing Non-English Help Files from Language Packs Troubleshooting Startup is Slow Updating the Software Results in a "(407) Proxy Authentication Required" Message Setting Up the Network to Send Crash Reports Installing on Top of an Existing Version Results in Unexpected Behavior iĤ Running the Legacy DPUPDATE.EXE Does Not Work Contact Hexagon Manufacturing Intelligence Appendix A Recommended System Requirements Operating System Microsoft.NET Framework RAM CPU Graphics Hard Drive Display Connectivity Browser Anti-Virus Software Solutions for CMMs Using RS-232 Communications Providing LMS Licensing Information to the Installer from the Command Line Appendix B Understanding File Locations Public Documents Public Documents (Reporting Directory) Public Documents (Fixturing) Program Data Files User Data Files Required User Access Rights File System Registry Notes Appendix C First-Time Installation with Flexible Fixturing iiĥ Release Notes R1 SP7 PCD Fixed an issue with poor-quality diagnostics bitmaps on Vision systems with high-resolution cameras.